aplikasi: Rumah Sakit, Klinik Veteriner, Laboratorium Pangan, Universitas & perguruan tinggi, Laboratorium Farmasi, Laboratorium Kultur sel, Stasiun Bayi
Maks. Kacepetan 4000rpm
Maks.RCF 2268xg
Max.Capacity 6 * 50ml amba rotor
Rotor sing cocog rotors sudhut tetep
tampilan LCD
Panggil Model: KC40-T
Certification: CE, ISO13485, ISO9001, SFDA
Warranty Garansi 1 taun kanggo kabeh mesin, garansi 3 taun kanggo kompresor lan garansi 5 taun kanggo motor. Suku cadang lan pengiriman gratis sajrone garansi.
  • Description
  • Video
  • Specifications Technical
  • Rotor lan Aksesoris
  • Advantage competitive

The benchtop centrifuge KC40-T is available with numerous fixed-angle rotors. The extensive range of accessories can accommodate tubes from 2 ml to 50 ml. The maximum RCF of more than 2,680 x g is suitable for many application areas in clinical diagnostics, veterinary medicine, pharmaceutics, environmental analysis and industrial production, as well as universities and research facilities.

desain

● Metal omah, tutup logam, lan 304 # stainless steel kamar centrifuge sing autoclave-bisa lan deterjen tahan lan cairan disinfeksi.

● Aluminium alloy rotor.

● Jendhela pengamatan ing tutup kanggo kalibrasi kacepetan lan pangukuran swara.

● Kontrol mikroprosesor kanthi motor DC tanpa sikat tanpa pangopènan.

● LCD nampilake paramèter Speed, Timer, RCF.

1

Pangguna grapyak

● Otomatis tutup-kunci lan nyekeli sak rotor roto.

● rotors gampang diijolke.

● Ngatasi masalah otomatis kanthi indikasi kode kesalahan lan weker ing layar.

● "Mute" teknologi paten. Tingkat gangguan luwih murah tinimbang 55 desibel kanthi kecepatan rotasi paling dhuwur.

T4-L Centrifuge Klinis Kecepatan Rendah

Keslametan

● Diprodhuksi miturut peraturan safety internasional (contone IEC 61010)

● Safety Listrik tutup interlock, lawang ora bisa mbukak nalika rotor mlaku lan mesin ora mbukak nalika tutup mbukak lan kode kesalahan katon.

● Rilis tutup-kunci darurat nalika daya mati.

● Engsel gas kanggo pangayoman gulung tutup.

● pangayoman Safety digawe kanggo kacepetan liwat, boten seimbang kalebet lan diagnosa kesalahan otomatis etc kanggo njamin safety mesin wong.

T4-L Centrifuge Klinis Kecepatan Rendah

Range kacepetan (rpm) 0-4000rpm luwes Akurasi kacepetan ± 10 rpm
Kapasitas Maks (ml) 12 * 20ml Range RCF (xg) 0-2680xg luwes
Noise (dBA) ≦55dB(A) Jangkoan wektu 0-99 menit luwes
Ukuran (mm) 430x320x250mm Bobot net (tanpa rotor) 18KGS
Power supply AC 220V, 50HZ, 5A, 120W
No. rotor kapasitas Maks. Kacepetan Maks.RCF cathetan
NO.11683337299238923 rotor sudut 24 × 10 / 5ml 4000r / min 2680xg PP/PC tabung/Vacuum koleksi getih tabung
adaptor 24 × 2ml
adaptor 24 × 1.5ml
NO.21683337299382301 rotor sudut 6 × 50 ml 4000r / min 2680xg tabung PP/PC
adaptor 6 × 15 / 10ml
adaptor 6 × 5 / 2ml
Jeneng-4

1. Produsen centrifuge profesional, rega sing kompetitif.

2. ISO9001, ISO13485, CE, Sertifikasi SFDA, kabeh mesin ngalami pengujian kualitas sing ketat lan kemasan sing apik sadurunge transportasi.

3. Dhukungan teknis jangka panjang lan layanan pelanggan profesional ing saben tahap dodolan produk, pangiriman lan operasi.Tim layanan sing mumpuni lan berpengalaman sing menehi sampeyan tingkat dhukungan sing unik kanggo tuku kanggo kabeh umur.

4. Kita uga bisa menehi solusi khusus kanggo syarat khusus klien.

5. Powered karo tim efisien engineers digawe dening taun pengalaman ing lapangan pamilike, perusahaan njamin saben produk sing ninggalake unit Manufaktur nganti tandha ing kabeh babagan.

PANALITEN
0
Kranjang penyelidikan
    Cart priksaan sampeyan kosong